3
Motor Protection Relay REM 610
Features Three-phase thermal overload protection
Three-phase motor start-up supervision
based on thermal stress calculation with
speed switch blocking ability
Three-phase overcurrent protection with
definite-time characteristic and speed
switch blocking ability
Three-phase short-circuit protection with
instantaneous or definite-time characteris-
tic
Three-phase undercurrent (loss of load)
protection with definite-time characteristic
Non-directional earth-fault protection with
definite-time characteristic
Three-phase unbalance protection based
on the negative-phase-sequence current
with inverse definite minimum time charac-
teristic
Phase reversal protection based on the
negative-phase-sequence current
Cumulative start-up time counter with
restart inhibit function
Circuit-breaker failure protection
Temperature protection stages with defi-
nite-time characteristic
Emergency start function
Optional RTD module
- with six measuring inputs
- supports PTC thermistors and various
RTD sensors
- three additional galvanically isolated
digital inputs
Disturbance recorder
- recording time up to 80 seconds
- triggering by one or several internal or
digital input signals
- records four analogue channels and up
to eight user-selectable digital channels
- adjustable sampling rate
Time synchronization via a digital input
Non-volatile memory for
- up to 100 event codes with time stamp
- setting values
- disturbance recorder data
- recorded data of the five last events with
time stamp
- number of starts for protection stages
- operation indication messages and
LEDs showing the status at the moment
of power failure
Battery back-up for real-time clock
Battery charge supervision
Four accurate current inputs
Two galvanically isolated digital inputs and
three additional digital inputs on the
optional RTD module
Time synchronization via a digital input
All settings can be modified with a PC
HMI with an alphanumeric LCD and
manoeuvring buttons
- eight programmable LEDs
Detachable plug-in unit
Three normally open power output contacts
Trip-circuit supervision
Two change-over signal output contacts
Output contact functions freely config-
urable for desired operation
Optical front communication connection:
wirelessly or via cable
Optional rear communication module with
plastic fibre-optic, combined fibre-optic
(plastic and glass) or RS-485 connection
for system communication using the SPA-
bus, IEC 60870-5-103 or Modbus (RTU
and ASCII) communication protocol
Continuous self-supervision of electronics
and software. At an internal relay fault, all
protection stages and outputs will be
blocked.
User-selectable rated frequency 50/60 Hz
User-selectable password protection for
the HMI
Display of primary current values
Demand values
Multi-language support
1MRS 755121
Issued: 01.12.2003
Status: Updated
Version: C/08.03.2005
Data subject to change without notice

Other manuals for ABB RE 610 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RE 610 Series and is the answer not in the manual?

ABB RE 610 Series Specifications

General IconGeneral
BrandABB
ModelRE 610 Series
CategoryRelays
LanguageEnglish

Related product manuals