ABB REF615 K User Manual

ABB REF615 K
896 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Relion
®
Protection and Control
615 series
Technical Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB REF615 K and is the answer not in the manual?

ABB REF615 K Specifications

General IconGeneral
TypeFeeder Protection Relay
Rated Frequency50/60 Hz
Rated Voltage100-240 V AC/DC
Rated Current1 A / 5 A
Communication ProtocolsIEC 61850, Modbus, DNP3
Protection FunctionsOvercurrent, earth fault, thermal overload
Operating Temperature Range-25°C to +55°C
Ingress ProtectionIP20
MountingFlush mounting

Summary

Section 1 Introduction

Product documentation

Details the product documentation set, including guides, manuals, and diagrams.

Functions, codes and symbols

Lists all available functions, their IEC 61850, IEC 60617, and IEC-ANSI identifications.

Section 2 615 series overview

Overview

Introduces the 615 series IEDs for protection, control, measurement, and supervision in substations and industrial switchgear.

Local HMI

Describes the Local Human-Machine Interface (LHMI) used for setting, monitoring, and controlling the IED.

Communication

Covers the communication protocols supported by the IED, including IEC 61850, IEC 60870-5-103, and Modbus.

Section 3 Basic functions

General parameters

Lists analog input settings for phase currents, residual current, and phase voltages.

Self-supervision

Explains the IED's self-supervision system for software and electronics, including internal faults and warnings.

Settings

Details the settings for programmable LEDs, including alarm color and alarm mode.

Fault records

Details the IED's capacity to store and analyze fault records, including current values, start duration, and operate time.

Binary input

Explains binary input settings, including filter time, inversion, and oscillation suppression.

Binary outputs

Lists the available binary outputs used for tripping, control actions, and signaling.

GOOSE function blocks

Explains the use of GOOSE function blocks for connecting incoming GOOSE data to the application.

Type conversion function blocks

Describes function blocks for converting data types, such as QTY_GOOD, QTY_BAD, QTY_GOOSE_COMM, and T_F32_INT8.

Section 4 Protection functions

Three-phase current protection PHxPTOC

Covers three-phase non-directional overcurrent protection, including identification, function block, functionality, and operation principle.

Three-phase non-directional overcurrent protection PH3xPTOC

Details three-phase non-directional overcurrent protection, including identification, function block, functionality, and operation principle.

Three-phase directional overcurrent protection DPHxPDOC

Explains three-phase directional overcurrent protection, covering identification, function block, functionality, and operation principle.

Directional earth-fault protection DEFxPDEF

Covers directional earth-fault protection, including identification, function block, functionality, operation principle, and application.

Transient/intermittent earth-fault protection INTRPTEF

Details transient/intermittent earth-fault protection, including identification, function block, functionality, operation principle, application, signals, settings, and technical data.

Admittance-based earth-fault protection EFPADM

Explains admittance-based earth-fault protection for high-resistance earthed, unearthed, and compensated networks.

Harmonic based earth-fault protection HAEFPTOC

Describes harmonic based earth-fault protection for networks with low fundamental frequency component.

Line differential protection and related measurements, stabilized and instantaneous stages LNPLDF

Details line differential protection for distribution network lines and cables, including stages, operation logic, and application.

Stabilized and instantaneous differential protection for 2W transformers TR2PTDF

Covers differential protection for two-winding transformers and generator-transformer blocks.

Motor load jam protection JAMPTOC

Explains motor load jam protection for stall or mechanical jam situations during the running state.

Three-phase thermal overload protection for motors MPTTR

Details thermal overload protection for motors, considering two time constants.

Three-phase thermal protection for feeders, cables and distribution transformers T1PTTR

Describes three-phase thermal protection for feeders, cables, and distribution transformers.

Negative-sequence overcurrent protection for motors NSPTOC

Covers negative-sequence overcurrent protection for motors, including identification, function block, functionality, operation principle, and signals.

Section 5 Protection related functions

Three-phase inrush detector INRPHAR

Details the three-phase inrush detector, its identification, function block, functionality, and operation principle.

Circuit breaker failure protection CCBRBRF

Explains circuit breaker failure protection, including identification, function block, functionality, operation principle, signals, settings, and monitored data.

Master trip TRPPTRC

Covers the master trip function, including identification, function block, functionality, operation principle, signals, settings, and technical revision history.

Binary signal transfer BSTGGIO

Details the binary signal transfer function, including identification, function block, functionality, operation principle, signals, and settings.

Emergency startup ESMGAPC

Explains the emergency startup function, including identification, function block, functionality, operation principle, application, signals, settings, and monitored data.

Switch on to fault control CBRSOF

Covers the switch on to fault control function, including identification, function block, functionality, operation principle, application, signals, and settings.

Uncorresponding position startup UPSCBR

Details the uncorresponding position startup function, including identification, function block, functionality, operation principle, application, signals, settings, and technical data.

Section 6 Supervision functions

Trip circuit supervision TCSSCBR

Explains trip circuit supervision, including identification, function block, functionality, operation principle, application, signals, settings, and monitored data.

Current circuit supervision CCRDIF

Details current circuit supervision, including identification, function block, functionality, operation principle, signals, settings, monitored data, and technical data.

Protection communication supervision PCSRTPC

Covers protection communication supervision, including identification, function block, functionality, operation principle, signals, settings, and monitored data.

Fuse failure supervision SEQRFUF

Explains fuse failure supervision, including identification, function block, functionality, operation principle, application, signals, and settings.

Section 7 Condition monitoring functions

Circuit breaker condition monitoring SSCBR

Details circuit breaker condition monitoring, including identification, function block, functionality, operation principle, and signals.

Section 8 Measurement functions

Basic measurements

Covers basic measurements like current, voltage, residual current/voltage, sequence components, and frequency.

Three-phase current measurement CMMXU

Details three-phase current measurement, including identification, function block, signals, settings, monitored data, and technical data.

Three-phase voltage measurement VMMXU

Explains three-phase voltage measurement, including identification, function block, signals, settings, monitored data, and technical data.

Residual current measurement RESCMMXU

Details residual current measurement, including identification, function block, signals, settings, monitored data, and technical data.

Residual voltage measurement RESVMMXU

Explains residual voltage measurement, including identification, function block, signals, settings, and monitored data.

Frequency measurement FMMXU

Covers frequency measurement, including identification, function block, signals, settings, and technical data.

Sequence current measurement CSMSQI

Details sequence current measurement, including identification, function block, signals, and settings.

Sequence voltage measurement VSMSQI

Explains sequence voltage measurement, including identification, function block, signals, and settings.

Three-phase power and energy measurement PEMMXU/MPEMMXU

Covers three-phase power and energy measurement, including identification, function block, signals, settings, monitored data, and technical data.

Disturbance recorder

Details the disturbance recorder functionality, including recorded analog inputs, triggering alternatives, and operation modes.

Section 9 Control functions

Circuit breaker control CBXCBR, Disconnector control DCXSWI and Earthing switch control ESXSWI

Covers control functions for circuit breakers, disconnectors, and earthing switches, including identification, function blocks, functionality, and operation principle.

Synchronism and energizing check SECRSYN

Explains synchronism and energizing check, including identification, function block, functionality, operation principle, signals, settings, and technical data.

Autoreclosing DARREC

Details the autoreclosing function, including identification, function block, functionality, operation principle, signals, settings, and monitored data.

Tap changer control with voltage regulator OLATCC

Covers tap changer control with voltage regulator, including identification, function block, functionality, operation principle, signals, settings, monitored data, and technical data.

Section 11 General function block features

Definite time characteristics

Explains definite time operation and its parameters.

Current based inverse definite minimum time characteristics

Details IDMT curves for overcurrent protection, including standard and user-programmable inverse-time characteristics.

Voltage based inverse definite minimum time characteristics

Explains IDMT curves for undervoltage protection, including standard and user-programmable inverse-time characteristics.

User-programmable inverse-time characteristics for overvoltage protection

Describes how users can define curves for overvoltage protection using standard formulas.

Section 12 Requirements for measurement transformers

Current transformers

Covers current transformer requirements for non-directional overcurrent protection, accuracy class, and accuracy limit factor.

Section 13 IED physical connections

Section 14 Technical data

RTD/mA inputs

Covers RTD/mA inputs, including supported sensors, resistance range, and accuracy.

Section 15 IED and functionality tests

Section 17 Glossary