Do you have a question about the ABB REB650 and is the answer not in the manual?
Product ID | REB650 |
---|---|
Product Type | Relay |
Frequency | 50/60 Hz |
Current Input | 1 A / 5 A |
Enclosure | IP54 |
Type | Line Differential Protection Relay |
Application | Protection, control, measurement and supervision of overhead lines and cables |
Rated Voltage | 100-250 V AC/DC |
Communication Protocols | IEC 61850, IEC 60870-5-103, Modbus, DNP3 |
Protection Functions | Differential protection |
Inputs | Binary inputs, Analog inputs |
Outputs | Binary outputs |
Operating Temperature | -40 to +70 °C |
Mounting Type | rack mounting |
Introduces the purpose and scope of the point list manual for DNP3 data points.
Describes the target users and their required knowledge for this manual.
Outlines the set of documents available for the product, detailing their use across the lifecycle.
Details the history of revisions for the document, including dates and changes.
Lists related documents and their respective document numbers for further reference.
Explains the various symbols used in the document for warnings and information.
Describes conventions for text formatting, HMI navigation, and signal naming.
Provides an overview of the DNP3 data points and structures available within the IEDs.
Introduces the table listing DNP3 signals and their properties for the IEDs.
Presents the device profile document in standard DNP3 format, defining capabilities and configurations.
Details the parameters and configuration for serial communication ports (RS485).
Describes IP networking parameters, including port names, IP addresses, and subnet masks.
Covers DNP3 link layer parameters like addresses, retries, and timeouts for confirmation.
Details application layer parameters such as fragment sizes, timeouts, and object limits.
Specifies parameters for outstation configuration, time synchronization, and response handling.
Covers support for secure authentication and its versions within DNP3 devices.
Details various broadcast functionalities supported by the DNP3 protocol.
Discusses static variations and event reporting for binary inputs, including buffer organization.
Covers static and event variations for double-bit binary inputs and their event buffering.
Details parameters for binary outputs and commands, including pulse times and event reporting.
Covers static and event variations for counters and frozen counters, including roll-over behavior.
Discusses static variations and event reporting for analog inputs, including deadband settings.
Details static and event variations for analog outputs and commands, and their event buffering.
Covers file transfer support within the DNP3 protocol.
Provides a table mapping DNP object groups to supported variations, function codes, and qualifiers.
Provides an alphabetical list of terms and their definitions used in the manual.