Relion
®
670 series
Bay control REC670 2.1 IEC
Product guide
Question and Answer IconNeed help?

Do you have a question about the ABB REC670 2.1 IEC and is the answer not in the manual?

ABB REC670 2.1 IEC Specifications

General IconGeneral
StandardIEC 61850
Rated Frequency50/60 Hz
Frequency Range45-65 Hz
Communication ProtocolsIEC 61850, IEC 60870-5-103, DNP3, Modbus
Input Voltage Range48-250 V DC or 110-230 V AC
CybersecurityRole-based access control
Mounting19-inch rack
Protection FunctionsOvercurrent, Distance

Summary

1. Application

2. Available functions

Main protection functions

Details primary protection functions like differential protection, with quantity examples.

3. Control

Synchrocheck, Energizing Check, and Synchronizing (SESRSYN)

Explains synchronizing function for controlled closing of circuit breakers in asynchronous networks.

Autorecloser (SMBRREC)

Describes the autorecloser function for high-speed and delayed auto-reclosing of circuit breakers.

4. Differential protection

1Ph High Impedance Differential Protection (HZPDIF)

Details the HZPDIF function for high-impedance restricted earth fault protection and differential protection.

5. Current protection

Instantaneous Phase Overcurrent Protection (PHPIOC)

Covers the PHPIOC function for fast, high-set short-circuit protection with low transient overreach.

Four-Step Phase Overcurrent Protection (OC4PTOC)

Explains OC4PTOC function with inverse or definite time delay for four steps, supporting directional options.

6. Voltage protection

Two-Step Undervoltage Protection (UV2PTUV)

Details UV2PTUV for detecting undervoltages to open breakers or as backup to primary protection.

7. Frequency protection

8. Multipurpose protection

General Current and Voltage Protection (CVGAPC)

Explains CVGAPC for negative sequence current protection and improving phase selection for earth faults.

9. Secondary system supervision

10. Scheme communication

Scheme Communication Logic for Distance/Overcurrent Protection (ZCPSCH)

Details ZCPSCH for instantaneous fault clearance using communication schemes for line faults.

Scheme Communication Logic for Residual Overcurrent Protection (ECPSCH)

Details ECPSCH for fast fault clearance of earth faults using directional residual overcurrent protection with communication.

11. Logic

Tripping Logic (SMPPTRC)

Covers SMPPTRC for protection tripping, ensuring trip pulse length and autoreclosing co-operation.

12. Monitoring

Measurements (CVMMXN, CMMXU, VNMMXU, VMMXU, CMSQI, VMSQI)

Covers measurement functions for obtaining online IED information like voltage, current, power, and phasors.

Disturbance Report Functionality (DRPRDRE)

Explains DRPRDRE for reliable disturbance information, including event logging, and saving data in Comtrade format.

14. Human machine interface

Local HMI (LHMI)

Describes the Local Human Machine Interface, its graphical display, navigation, LEDs, and communication port.

16. Station communication

Communication Protocols

Lists available communication protocols like IEC 61850, LON, SPA, and DNP3 for connecting IEDs to substation systems.

18. Hardware description

Hardware Modules Overview

Lists various I/O and communication modules including PSM, BIM, BOM, SOM, IOM, MIM, OEM, SLM.

Related product manuals