Operation Manual / TPL67-C.. - TPL71-C..
Disassembly and assembly
8
Installing cartridge group
8.7
Page 94
© Copyright 2016 ABB. All rights reserved.
April 2016 HZTL2488_EN Revision C
Remove the cover from the oil connection.
Fasten separate lifting gear to each of the two ribs on the bearing cas-
ing provided for this purpose.
Remove supports (90450) and carefully insert cartridge group.
CAUTION
If the rotor blades have insufficient or no clearance, the blades and cas-
ing could be damaged.
Turn rotor to check that blades do not rub against turbine diffuser.
Uniformly tighten the three screws (61059) with Verbus Ripp® wash-
ers (61058).
Remove the lifting gear.
Screw in the speed sensor (86505) along with the O-ring (86506) and
plug in the cable connector (86515).