EasyManua.ls Logo

ABB TPL65-A32 - Page 34

ABB TPL65-A32
129 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Commissioning
3
Oil supply
3.1
Page 32
September 2014 HZTL2498_EN Revision A
Oil pressure
The oil pressure in front of the turbocharger must be maintained precisely
to ensure trouble-free operation.
The permissible oil pressure ranges at measuring point M (blind
connection) on the turbocharger are listed below.
Status for operation
Oil pressure in front of the
turbocharger [bar]
Permissible, for normal operation
1.32.5
Permissible, during engine warm-up 1.35.0
Temporarily permissible ( < 1h ) -> alarm
1.11.3
Not permissible ->
emergency stop
0.01.1
Permissible, during pre- and post-lubrication
(engine stopped)
0.22.5
NOTICE
Oil orifice
To make sure these oil pressures are obtained, a regulating orifice is
fitted in the turbocharger oil inlet. The orifice is fitted by the engine
builder and secured by a safety ring.