Sluggish start-up
Possible causes
Elimination
Turbocharger Dirty turbocharger Clean it.
Damaged bearing
Contact ABB Turbocharging
Service Station.
Touching rotor
Foreign matter in turbocharger
Vibration
Possible causes
Elimination
Turbocharger Rotor unbalance Contact ABB Turbocharging
Service Station.
Damaged turbine or
compressor
Damaged bearing
Rubbing of rotating parts
Normal behaviour, no malfunction
Turbocharger Minor uniform wear around the periphery of rotor components,
caused by slight local rubbing of adjacent components, is
permissible. The compressor blades and turbine blades are
then shortened somewhat. Certain tolerances must be observed
to avoid a significant loss of efficiency.
If there is any doubt about the extent of rubbing, then an ABB
Turbocharging Service Station must be contacted.
Have a dimension check carried out by an ABB
Turbocharging Service Station.