Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS 52D01 HT842179
n
Mmax
856 t
Mmax
650
n
Bmax
813 t
Bmax
620
1/s °C
00250 8 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2410 English
TPS 52D01
Original Operation Manual

Table of Contents

Questions and Answers

  • C
    Cassandra YoungSep 13, 2025
    How to fix fouling of the compressor in ABB Battery Charger?
    • J
      Jonathan MuellerSep 13, 2025
      If the compressor of your ABB Battery Charger is fouling due to the feeding in of ventilation gases, it may be caused by heavy fouling of the compressor components, requiring you to clean the compressor. It may also be caused by increased vibrations or compressor blade damage, in which case you should correct the feed of ventilation gases according to instructions of enginebuilder.
  • A
    akelleySep 12, 2025
    Why ABB Battery Charger has increase in speed?
    • A
      Allison RobertsonSep 12, 2025
      If your ABB Battery Charger has an increase in speed, it could be due to a heavily contaminated nozzle ring (with 4-stroke application). In this case, you should contact an ABB Turbocharging Service Station.
  • B
    Bryan BaileySep 12, 2025
    What to do if measured speeds are too high in ABB Battery Charger?
    • H
      Heather KingSep 12, 2025
      If your ABB Battery Charger measured speeds are too high, the sensor tip may be contaminated. Dismantle the sensor, clean its tip, and refit the sensor using the specified tightening torque.
  • K
    Kristina LawsonSep 10, 2025
    Why ABB Battery Charger run-down time is too short?
    • D
      Debra DiazSep 10, 2025
      If your ABB Battery Charger run-down time is too short, the turbocharger may be contaminated, requiring cleaning. Alternatively, there may be a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • S
    Shawn JonesSep 9, 2025
    Why ABB Battery Charger makes noises during run-down?
    • R
      robert44Sep 9, 2025
      If your ABB Battery Charger is experiencing noises during run-down, the turbocharger may be contaminated, requiring cleaning. Alternatively, there may be a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • D
    donnabrownSep 8, 2025
    What causes charge air pressure to be too high in ABB Battery Charger?
    • M
      mark68Sep 8, 2025
      If the charge air pressure of your ABB Battery Charger is too high, it could be due to a malfunctioning or poorly adjusted injection system. You should repair it or contact the manufacturer, or correct it.
  • V
    vanessapetersAug 23, 2025
    Why is my ABB Industrial Equipment vibrating?
    • S
      Stephen KleinAug 23, 2025
      If your ABB Industrial Equipment is experiencing vibrations, it could be due to a rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. It may also be caused by a damaged turbine, compressor, or bearing.
  • G
    Glenda BlairSep 6, 2025
    What to do if charge air pressure is too low in ABB Battery Charger?
    • B
      Brian HowardSep 6, 2025
      If the charge air pressure of your ABB Battery Charger is too low, the air receiver may be leaking, requiring repairs. The injection system might be poorly adjusted, needing correction. A wrong reading on the manometer may also be the reason, in this case you should replace the manometer. A contaminated filter silencer causing excessive loss of pressure could also be responsible, and you should clean it.
  • J
    joseph17Sep 5, 2025
    Why my ABB Battery Charger has vibrations?
    • T
      taylorkatelynSep 5, 2025
      If your ABB Battery Charger is experiencing vibrations, the rotor may be unbalanced. In this case, you should contact an ABB Turbocharging Service Station.
  • J
    John DavisSep 4, 2025
    Why ABB Battery Charger has reduction in speed?
    • D
      David AlvaradoSep 4, 2025
      If your ABB Battery Charger has a reduction in speed, one potential cause is defects of connected cylinders when pulse charging, in which case you should contact the enginebuilder. Another reason could be heavy contamination of the turbine, and you should clean it. Defects such as leaks in the exhaust gas pipes or charge air ducts could also be responsible, and you should make repairs.