Operation Manual / TPS48-D/E.. - TPS61-D/E..
Taking out of operation
9
Shutting down the turbocharger
9.1
Page 114
April 2015 HZTL2410_EN Revision D
Close the opening in the turbine casing using the cover plate (A).
Fasten the cover plate on the turbine casing (51000) using the
fastening strips (51002), Verbus Ripp® Verbusripp washers (51003)
and nuts (51007) and screw it down securely on the support.
NOTICE
Thoroughly clean the fastening strips (51002) before fitting them. Apply
high-temperature grease to the stud threads (51006).
© Copyright 2015 ABB. All rights reserved.