3.3.2 Sensor Dimensions
DN 3 to 32 Full Bore
Note. Lay length – all sensors conform to ISO13359.
Fig. 3.20 DN 3 to 32 Full Bore
Meter Size Dimensions mm (in)
DN NPS/NB A* B**
3 to 8 0.12 to 0.31 90 (3.54) 130 (5.11)
10 0.40 90 (3.54) 200 (7.87)
15 0.60 95 (3.74) 200 (7.87)
20 0.79 105 (4.13) 200 (7.87)
25 1.0 115 (4.53) 200 (7.87)
32 1.26 140 (5.51) 200 (7.87)
*Dimensions are approximate and vary depending on flange type
**Typical tolerance: +0/–3 mm (0.12 in)
Table 3.1 DN 3 to 32 Full Bore (PN/ANSI150)