EasyManua.ls Logo

ABB WaterMaster - Specification - Sensor; Non-wetted parts; Flange material; Housing material

ABB WaterMaster
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electromagnetic Flowmeter
WaterMaster 6 Specification
IM/WM Issue 7 41
Sensor – Physical Specification
Non-wetted Parts
Flange material
Carbon steel
Housing material
Carbon steel (sizes DN40 to 200 [1
1
/2 to 8 NB]
and DN700 to 2200 [28 to 84 NB])
Plastic (sizes DN250 to 600 [10 to 24 NB])
Terminal box material
Polycarbonate or aluminium
Cable gland material
Plastic or brass
Transmitter – Functional Specification
Power supply
Supply voltage fluctuations within the specified range have no
effect on accuracy
Digital Outputs (3 off)
1 off dedicated to Alarm/ Logic, programmable function
2 off configurable to either Pulse/Frequency or Alarm/Logic function
Current output
4 to 20 mA or 4 to 12/20 mA, galvanically isolated
Maximum loop resistance 750 Ω
HART protocol Version 5.7
Signal levels compliant with NAMUR NE 43 (3.8 to 20.5 mA)
Low alarm 3.6 mA, High alarm 21.8 mA
Additional accuracy
Electrical connections
20 mm glands,
1
/2 in NPT, 20 mm armored glands
Temperature limitations
Environmental protection
Humidity: 0 to 100 %
Rating: IP67 (NEMA 4X) to 1m (3.3 ft) depth
Mains 85 to 265 V AC @ <7 VA
Low voltage 24 V AC +10 %/–30 % @ <7 VA
DC 24 V ±30 % @ <0.4 A
Rating 30 V @ 220 mA, open collector, galvanically isolated
Maximum output frequency 5250 Hz
±0.1 % of reading
Temperature coefficient Typically <±20 ppm/°C
Ambient temperature –20 to 60 °C (–4 to 140 °F)
Temperature coefficient Typically <±10 ppm/°C @ Vel 0.5 mls