EasyManuals Logo

ABL Wallbox eMH2 User Manual

ABL Wallbox eMH2
Go to English
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Wallbox eMH2 – Testing the RCCB |
27
English
Testing the RCCB
To ensure the continuing safe operation of the wallbox, the function of the RCCB must be tested regularly
according to locally applicable regulations (e.g. every 6months in Germany): For this purpose, the RCCB
has a push button with which to initiate the test function.
Proceed as follows to test the RCCB:
1 Open the housing cover of the wallbox with
the housing cover key and put it aside.
2 Open the access flap of the internal electronic
components cover.
3 Locate and press the push button engraved T
or marked Test.
y The RCCB must now trip and flick its pivot
lever into the centre position.
4 Now flip the pivot lever first to the 0 position
and then back to the I position.
5 Close the access flap, hook the housing cover
onto the upper edge of the housing base and
lock it using the housing cover key.
Danger
Dangerous electrical currents
Should the RCCB malfunction during testing, you must not continue to operate the wallbox under any
circumstances!
Contact a qualified specialist electrical contractor to have the error resolved.

Table of Contents

Other manuals for ABL Wallbox eMH2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABL Wallbox eMH2 and is the answer not in the manual?

ABL Wallbox eMH2 Specifications

General IconGeneral
BrandABL
ModelWallbox eMH2
CategoryAutomobile Battery Charger
LanguageEnglish

Related product manuals