24
CONNECTION EXAMPLES
Electric locks EL402, EL404, EL502
Motor locks EL490, EL590
12345678910
1112
+24 out
Normal
Not
Locking
GND
circuit
in use
impulse
Fire
detector
+12V out
Delayed
impulse
GND
gray
blue
red
green
white
black
blue
red
green
12345678910
1112
+24 out
Normal
Not
Locking
GND
circuit
in use
impulse
Fire
detector
+12V out
Delayed
impulse
GND
NOTE! Not to be installed in doors with seal force.
Bolt and trigger bolt have to be lubricated
when lock is installed and when necessary.