GENERAL INFORMATION
Technical data
Measures
• 595 (L) x 85 (H) x 107 (W) mm
• Weight 6,5 kg
• Supply voltage 90-264 VAC, 47-63 Hz
• Rated output 70 W
• Enclosure class IP20
Temperature range
• Storage -30...+85°C (in dry premises)
• Operation: -15...+50°C (in dry premises)
• The automatic swing door operator must not be installed in applications where it is
subjected to water or snow.
Interfaces
• Voltage output 24 VDC, stabilized, output current 500 mA
• Voltage output 12 VDC, stabilized, output current 1,0 A
• The total load must not exceed 12W
• Potential free relay output, preset to operate 2 seconds
2 A @ 30 VDC resistive load
Features
• Usage for heavy density of pedestrian traffi c
• Push&Go as a standard feature
• Normal and delayed impulse
• Adjustable hold open time 0...60 s or sequential use
• Fire detector connection
• Free Swing operation
• Door hold force
• Prepull before opening
• Secondary DC inlet for power back up (24 VDC (•±15 %), 3A)
• Maximum opening angles:
With standard arm 100 degrees
With sliding arm on the opening side 100 degrees
With sliding arm on the closing side 90 degrees