A SAFE DOOR
The safety of the door operator is controlled by basic adjustments; operator force, speeds, and hold open times.
• The operator force is an important adjustment. A high value affects to the safety feature and also to its
sensitivity.
• High speeds increases the energy transferred in the door causing it not stop correctly.
• With hold open times the distance from impulse device to door is preset.
1. Adjust low speeds.
2. Adjust the operator force to a low setting ensuring the safety feature activates on door moving.
3. Adjust the hold open times.
By following these basic procedures the operator is safe in operation.
Note!!! High speeds and safety is only possible by fi tting of Safety sensors.
REMEMBER!
With using safety sensors to opening and closings sides and activating self diagnostics, the door environment
will be safe and meets the EN 16005-standards.
Note. fi ll the included EN 16005 checklist.