ON The slave unit has opening delay of 0,5 sec.
OFF The slave unit has a standard opening delay of 0,2 sec.
FS6 Slave delay
FS7 Master/Slave
FS8 Push & Go
NOTE! Keep the mains disconnected, while changing dip switch.
ON Two pieces normal DB operators. Slave operator.
OFF Two pieces normal DB operators. Master operator.
ON
A push on the door will, from closed position, start an automatic opening
cycle if the programme selection is AUTO and remain open during the hold
open time Outer HOT (0-30 s).
A home switch (DB102) on the operator is needed to achieve Push to Go.
OFF Push & Go is not in use.