5
EN1154 classification.
TECHNICAL SPECIFICATIONS
·Mains power supply: 230 VAC (-10 - +10 %), 50 Hz, fuse 10 A
·Power consumption: max 230 W
·Auxliary voltage : stabilized 24 VDC, 700 mA
·Motor Fuse: 6,3 AT
·Control unit fuse: 250 mAT
·Class of protection IP20
·Dimensions: 716 mm x 110 mm x 110 mm (Length, Depth, Height)
·Weight: 11 kg
·Operation: -15...+30°C (in dry premises)
·The automatic swing door operator must not be installed in applications where it is subjected
to water or snow.
·Maximum recommended door weight/width:
Standard arm: 250 kg / 1600 mm
Sliding arm: 100 kg / 1400 mm
·Limit switch (DB102): 1A, 48 VDC, NO
Note the maximum door weight in fire doors. Class 6 door closer will
close door 120kg / 1400 mm
.
Mount a door stop to the door open position so that wind will not drive
the door against the wall, resulting in damage
Class Standard arm Sliding arm Closing
torque
Door weight[kg] Door weight[kg] [Nm]
/ width[mm] / width[mm] (0-4°)
1 20 / 750 9
2 40 / 850 13
3 60 / 950 60 / 950 18
4 80 / 1100 80 / 1100 26
5 100 / 1250 37
6 120 / 1400 54