TECHNICAL DETAILS ENGLISH
Operating voltage: 12 - 24 V DC (± 15%)
12 - 18 V AC (-10% / +15%), RMS
Current: 12 V DC 80 mA Idle
450 mA normal driver
1300 mA max.
24 V DC 40 mA Idle
220 mA normal driver
600 mA max.
Relays: Max. 0.8 A 30 V AC/DC resist. 20 W
Operating temperature: -20°C - +60°C
Bolt throw: 20 mm (deadbolt), 10 mm (double action bolt)
Backset: 55, 60, 65, 80, 100 mm (EL520, EL522)
30, 35, 40, 45 mm (EL420, EL422)
Forend: 20, 24 mm (EL520, EL522)
24, 28 mm (EL420, EL422)
Spindle: 9 mm (8 mm with snap spindle adapter)
Connection cable: EA218 (6 m) / EA219 (10 m) 18 x 0.14 mm2
Adjustable delay: 2 - 15 s
Door clearance: 2 - 5.5 mm (between forend and strike plate)
Settable functions: Mechanical functions:
- Opening direction of trigger bolt
Monitoring outputs: Bolt deadlocked
Lock open
Trigger bolt in
Handle used
Cylinder used
Sabotage
Strike plate: EA321, EA322, EA323, EA324, EA325, EA326, EA327, EA328,
EA329, EA330, EA331, EA332
The use of a universal building key is prohibited because it can seriosly damage the lock.
TESTED ACCORDING TO THE STANDARDS
EN 179 3 7 6 1 1 3 2 2
Exit
EN 1125 3 7 6 1 1 3 2 1/2
Panic exit
EN 1634-1
Fire
EN 61000-6-1:2007
EMC
EN 61000-6-3:2007
EMC