Configuration parameter



Para-
meter
Name Unit Setting


values
Default
setting
Field
size
(byte)

Notes
1 
holding
time
Second 1 - 20 3 1 Current holding
time of latch,
settable to
intervals of
between 1 and
20 seconds.
2 
force
 1 - 3 2 1 Setting of
current torque
during travel of
latch

- 2 medium
(standard)
- 3 low
(min.)
3 Acoustic
signal
Value 1 - 5 3 1 Setting of
acoustic signals
to the follo-
wing values:
- 1 all signals
inactive
- 2 signal only
at start of
travel
- 3 signal when
latch positi-
on is reached
- 4 signal when
locked positi-
on is reached
- 5 signal when
end position
is reached
Button, low-
battery and

signals cannot
be changed.