41
Fig. 33 Multiplier map. Suggested area of petrol map acquisition.
Fig. 34 Multiplier map. Suggested area of gas map acquisition.
2.9.1. Multiplier matching
When 2/3 of the suggested area on gas and petrol map is acquired, button for multiplier matching
function is activated. The operation modifies the multiplier based on a deviation between the recorded
maps for petrol and gas injection. If map differences are minor, the multiplier is not modified.
It is recommended to acquire injection time maps for the full suggested range of
engine operation. Multiplier matching is locked when autoadaptation is active
(ISA3 or OBD).