Page 17 of 34 Copyright © Access-IS 2016
5. Command reference
Commands are sent with a prefix of [0x16][0x4D][0x0D] causing the command sequence to
take the form [0x16][0x4D][0x0D]<Menu Command>. The menu commands are six characters
long with a parameter (if required).
To send a command to modify a configuration parameter
Send the six-character command concluded by a dot ‘.’ or an exclamation mark ‘!’. The dot stores
the setting permanently and the exclamation mark keeps it temporarily until power is removed from
the device.
For example, [0x16][0x4D][0x0D]AISKBL1. sets the keyboard localisation to United States
when the device is operating as a USB keyboard.
To query the current settings (including a temporary one)
Send the six-character command with a ‘?’ instead of the parameter and the LSR116 will return the
command with the current setting.
For example, [0x16][0x4D][0x0D] AISINF? queries the device interface and returns the
current value.
To query the stored value
Send the six-character command with a ’^’ instead of the parameter and the LSR116 will return the
command with the stored setting.
For example, [0x16][0x4D][0x0D] AISINF^ returns the current illumination mode.
To list parameter options
Send the six-character command with a ‘*’ instead of the parameter and the LSR116 will return the
command with the parameter options.