Command
Description
Default
Parameters/Range
DLYGRD
Sets the delay between successful
reading of one barcode and the reading
of another barcode.
Each unit is equivalent to 1 millisecond.
2000
025000
5.2 Prefix and suffix solutions
These commands allow you to add a prefix and/or suffix to all barcodes.
Note: If you send more than one prefix or suffix to the device, they will stack in chronological order.
You must send a clear command if you want to use a single prefix or suffix.
Table 3. Prefix and suffix commands
Command
Description
Default
Parameters/Range
PREBK299xx
Adds a prefix to all barcode
symbologies.
Any two-character hex ASCII code can
replace xx.
For example, to add STX (Start of Text)
as a prefix, use the command
PREBK29902.
You can add more than one prefix, as
required.
-
xx - Hex value
PRECA2
Clears all prefixes.
-
-
SUFBK299xx
Adds a suffix to all barcode
symbologies.
Any two-character hex ASCII code can
replace xx.
You can add more than one suffix, as
required.
For example, to add CR (Carriage
Return) and ETX (End of Text) as a
suffix, use the command
SUFBK2990D03.
-
xx - Hex value
SUFCA2
Clears all suffixes.
-
-