Bit
Byte
7
6
5
4
3
2
1
0
0
[0x02]
1
[0x04]
2
[0x5D] - ‘]’
3
[0x51] - ‘Q’
4
[0x30] - ‘0’
5
[0x20]100
[0x00] [0x00]
...
[0x00] [0x00]
..
..
60
61
[0x73] - ‘s’
62
[0x00]
63
0
0
0
0
0
0
0
0
A.2 Send commands
To send commands to the LSR116, use a HID out report with the following structure:
Bit
Byte
7
6
5
4
3
2
1
0
0
Report ID = 253
1
Data length
2
Output data
(up to 62 bytes)
..
..
..
..
63
A.2.1 Example output report to request firmware version
This example requests the firmware version from the LSR116.
Bit
Byte
7
6
5
4
3
2
1
0
0
253
1
[0x0B]
2
[0x16][0x4D][0x0D]AISFWV1.
..
..
..
..
63