- 32 -
RDM functions: Certain menus of the device and functions can be called up via the RDM
protocol.
The parameter IDs are implemented as follows for different commands:
Parameter ID
Command
‘Discovery’
Command
‘Set’
Command
‘Get’
DISC_UNIQUE_BRANCH
√
DISC_MUTE
√
DISC_UN_MUTE
√
DEVICE_INFO
√
SUPPORTED_PARAMETERS
√
SOFTWARE_VERSION_LABEL
√
DMX_START_ADDRESS
√
√
IDENTIFY_DEVICE
√
√
DEVICE_MODEL_DESCRIPTION
√
PARAMETER_DESCRIPTION
√
MANUFACTURER_LABEL
√
DEVICE_LABEL
√
√
FACTORY_DEFAULTS
√
√
BOOT_SOFTWARE_VERSION_ID
√
BOOT_SOFTWARE_VERSION_LABEL
√
DMX_PERSONALITY
√
√
DMX_PERSONALITY_DESCRIPTION
√
SLOT_INFO
√
SLOT_DESCRIPTION
√
SENSOR_DEFINITION
√
SENSOR_VALUE
√
DEVICE_HOURS
√
LAMP_HOURS
√
PAN_INVERT
√
√
TILT_INVERT
√
√
RESET_DEVICE
√
CURVE
√
√
DMX_STATE
√
√
DIMMER_SPEED
√
√
√-Command implemented for the respective parameter ID