EasyManua.ls Logo

ACME SUPERNOVA - Page 56

ACME SUPERNOVA
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 55 -
Blade Reset Error
Base Fan1/2 Start Err
Base Fan1/2 Stop Err
Arm Fan Start Err
Arm Fan Stop Err
Check whether the fan circuit on the motherboard breaks down.
Check whether the component is damaged.
Check whether the fan circuit on the motherboard breaks down.
Check whether the component is damaged.
Check whether the fan is not running.
Check whether the fan leads are installed in place or disconnected.
Check whether the fan is damaged.
Check whether there are obstacles in the fan operating range.
Check whether the position of the blade where the magnet is
installed falls off or is damaged.
Check whether there are obstacles in the blade operating range.
Check whether the Hall element on the blade is damaged.
Check whether the lead connecting the Hall element on the blade and
the PCB board is in poor contact or disconnected.
Check whether the motor on the blade is damaged.
Check whether the related circuit of the motor drive board on the
blade is damage.
Check whether the fan is not running.
Check whether the fan leads are installed in place or disconnected.
Check whether the fan is damaged.
Check whether there are obstacles in the fan operating range.

Related product manuals