Head Fan1/2/3/4/5/6/7/8/9/10/11 Start Err
Head Fan1/2/3/4/5/6/7/8/9/10/11 Stop Err
Led Temp. Error
LED Timeout Use
LED Too Hot Off
AIOT-A Error
NTC Error
Head Humi. Too High
Disassemble the housing of the fixture to dehumidify.
The electronic components of the A board are faulty and the A board
needs to be replaced.
Check whether the power supply, battery and 485 (DATA) lead of the
AIOT module are plugged in properly.
Check whether the fan circuit on the motherboard breaks down.
Check whether the component is damaged.
When the fixture temperature reaches 86, it will automatically turn
off to protect the fixture.
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.
Check whether the fan is not running.
Check whether the fan leads are installed in place or disconnected.
Check whether the fan is damaged.
Check whether there are obstacles in the fan operating range.