Acterna OLS-55/-56 29
6 SPECIFICATIONS
6 SPECIFICATIONS
Technical data
Wavelengths
1)
OLS-55
- BN 2279/01, 21
- BN 2279/02, 22
- BN 2279/03, 23
OLS-56
1310/1550 nm
1310/1550/1625 nm
1310/1490/1550 nm
MM: 850/1300 nm
SM: 1310/1550 nm
Spectral width (RMS) 5 nm
Number of ports
- OLS-55
- OLS-56
Single port
Dual port
Fiber type
- OLS-55
- OLS-56
9/125
9/125, 50/125
Output power range
2)
CW
Modulated, Auto λ
-7.00 to 0.00 dBm
-10.00 to -3.00 dBm
Resolution of power
setting
0.01 dB
Signal stability
3)
- Short term
- Long term
± 0.02 dB (within 15 min.)
± 0.20 dB (within 8 h)
Tracking error ± 1dB
Modes - Continuous wave (CW)
- Modulated: 270 Hz, 1 kHz,
2kHz
- Auto λ
4)
1) typ. ± 20 nm
2) CW signal, T=23°C±3K, including connector, depending on
quality of connector applied to the OLS
3) At ambient temperature range -10 °C to +55 °C, ΔT=±0.3K
4) Signal coding for automatic power meter wavelength
detection. Works only with Acterna OLP-55.