EasyManua.ls Logo

ActronAir Classic 2 CRA230T User Manual

ActronAir Classic 2 CRA230T
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Classic Series 2
Split Ducted Unit
Installation and Commissioning Guide - Outdoor
Model Numbers
Classic Condenser Add On Cooling Only
CRA100S
CRA130S
CRA130T
CRA150S
CRA150T
CRA170S
CRA170T
CRA200T
CRA230T
CCA130S
CCA150S
CCA170S
CCA170T
CCA200T
CCA230T
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir Classic 2 CRA230T and is the answer not in the manual?

ActronAir Classic 2 CRA230T Specifications

General IconGeneral
BrandActronAir
ModelClassic 2 CRA230T
CategoryAir Conditioner
LanguageEnglish

Summary

01. Inspection

Product Inspections

Inspect unit, components, and accessories for damage upon receipt. Verify nameplate details.

03. Safety Instructions

Refrigerant Handling and Accountability

Urges technicians to minimize refrigerant emissions and act responsibly.

04. Installation Information

Recover and Recycle Refrigerants

Procedures for proper refrigerant recovery, recycling, and disposal as per Australian law.

Refrigerant Handling and Safety

Emphasizes consulting SDS, using approved vessels, and adhering to safety standards.

Service Equipment and Recovery Procedures

Details using appropriate equipment for minimizing emissions and achieving low vacuum.

INSTALLATION PREPARATION (Pre-Installation considerations)

Electrical Safety

Requirements for circuit breakers, RCDs, and securing cables as per Australian standards.

08. Unit Dimensions and Clearances

09. Unit Lifting Procedure

Fork Lift Method

10. Outdoor Unit Preparation

11. Field Pipe Connection

11.01. Piping and Brazing

Crucial precautions and techniques for brazing refrigerant pipes safely and effectively.

Nitrogen Bleed Procedure

11.02. Pressure Testing

11.03. Evacuation Procedure (Triple Evacuation)

12. Electrical Installation

12.01. Split Unit Electrical Connection

Circuit Breaker Size and Cable Size Requirement

17. Third Party Control Input (InZone Board and/or Outdoor Board)

19. Refrigerant Charging

19.01. Charging Method: Sub-cooling and Superheat

Explains charging methods using sub-cooling and superheat parameters.

19.01.02. Cooling and Heating Operation:

19.01.03. Checking For Sub-cooling

19.01.04. Checking for Superheat:

20. Maintenance

Troubleshooting Guide - System Issues

System Start and Airflow Problems

Solutions for when the system fails to start or indoor airflow is inadequate.

Insufficient Cooling/Heating Performance

Steps to resolve issues where cooling or heating capacity is insufficient.

Troubleshooting Guide - Operational Issues

Temperature Adjustment and Noise Issues

Solutions for inability to adjust temperature and occasional noises during heating.

Cooling/Freezing and Fan Issues

Addresses problems with system cooling, outdoor coil freezing, and single fan operation.

22. Fault And Status Codes

24. Start Up and Commissioning Report

Related product manuals