EasyManua.ls Logo

ActronAir Classic 2 CRA150S User Manual

ActronAir Classic 2 CRA150S
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Classic Series 2
Split Ducted Unit
Installation and Commissioning Guide - Outdoor
Model Numbers
Classic Condenser Add On Cooling Only
CRA100S
CRA130S
CRA130T
CRA150S
CRA150T
CRA170S
CRA170T
CRA200T
CRA230T
CCA130S
CCA150S
CCA170S
CCA170T
CCA200T
CCA230T
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir Classic 2 CRA150S and is the answer not in the manual?

ActronAir Classic 2 CRA150S Specifications

General IconGeneral
BrandActronAir
ModelClassic 2 CRA150S
CategoryAir Conditioner
LanguageEnglish

Summary

Inspection

Product Inspections

Check unit and components for damage upon receipt. Verify nameplate details.

Codes, Regulations and Standards

Ensure installation complies with local codes and electrical authority regulations.

General Information

Safety Instructions

Installation Information

Refrigerant Handling and Safety

Procedures for safe handling, recovery, and recycling of refrigerants.

INSTALLATION PREPARATION (Pre-Installation considerations)

Operation Manual Access

Near Field Communication (NFC) Tag

Use NFC technology on mobile devices to access operation manuals.

Components Overview

Control Panel

Single Phase (10-17kW)

Detailed view and description of the control panel for single-phase models.

Unit Dimensions and Clearances

CRA100S

Dimensions, weight, and clearance requirements for the CRA100S model.

Minimum Service Access Areas and Airflow Clearances

Specifies required clearances around the unit for service and airflow.

Unit Lifting Procedure

Outdoor Unit Preparation

Field Pipe Connection

Piping and Brazing

Guidelines and standards for piping and brazing refrigerant lines for R-410A systems.

Pressure Testing

Evacuation Procedure (Triple Evacuation)

Electrical Installation

Split Unit Electrical Connection

Circuit Breaker Size and Cable Size Requirement

Maximum Cable Lengths

Wiring Configuration : Recommended

Recommended wiring layout and maximum cable lengths for controllers and sensors.

Wiring Connections

LR7 Wall Control Wiring Connections

Detailed wiring for the LR7 Wall Controller.

Demand Response Management

Control Source Configuration (CtrS)

Third Party Control Input

Third Party Control Input (Single Speed Fan Operation)

Wiring and settings for third-party control of single-speed fan operation.

Indoor Fan Commissioning via Third Party Control

EVA100S / EFA100S

Performance data and charts for indoor fan commissioning for EVA100S/EFA100S.

EVA130S / EFA130S

EVA150S / EFA150S

EVA170S / EFA170S

EVA200S / EFA200S

EVA230S / EFA230S

Refrigerant Charging

Charging Method: Sub-cooling and Superheat

Explains how to charge refrigerant using sub-cooling and superheat methods.

Cooling and Heating Operation

Checking For Sub-cooling

Checking for Superheat

R-410A PRESSURE / TEMPERATURE CHART

Maintenance Procedures

Maintenance Frequency Checklist

Troubleshooting Guide

Fault And Status Codes

Key Parts List

Start Up and Commissioning Report