EasyManua.ls Logo

ActronAir Classic 2 CRA150T User Manual

ActronAir Classic 2 CRA150T
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Classic Series 2
Split Ducted Unit
Installation and Commissioning Guide - Outdoor
Model Numbers
Classic Condenser Add On Cooling Only
CRA100S
CRA130S
CRA130T
CRA150S
CRA150T
CRA170S
CRA170T
CRA200T
CRA230T
CCA130S
CCA150S
CCA170S
CCA170T
CCA200T
CCA230T
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir Classic 2 CRA150T and is the answer not in the manual?

ActronAir Classic 2 CRA150T Specifications

General IconGeneral
BrandActronAir
ModelClassic 2 CRA150T
CategoryAir Conditioner
LanguageEnglish

Summary

Inspection and Product Checks

Product Inspections

Verify air conditioning unit and accessories against invoice for damage. Check nameplate details.

Safety Instructions and Precautions

Safety Instructions

Guidelines for installation and service by licensed technicians, WH&S, and electrical safety.

Installation Information and Procedures

Refrigerant Handling and Recovery

Procedures for recovering, recycling, and handling refrigerants safely and legally.

Refrigerant Handling and Safety

Consult SDS for proper handling, health, safety, storage, and disposal requirements.

Unit Dimensions and Clearances

Outdoor Unit Preparation Steps

Outdoor Unit Preparation

Steps for preparing the outdoor unit for installation, including removing panels and earth cable.

Field Pipe Connection

Piping and Brazing Best Practices

Guidelines for R-410A refrigerant piping, brazing with nitrogen, and equivalent pipe length calculations.

Pressure Testing Procedure

Steps for pressurizing the system to 2500kPa in stages for testing.

Evacuation Procedure (Triple Evacuation)

Detailed steps for performing a triple evacuation to remove moisture and non-condensables.

Electrical Installation Guidelines

Electrical Installation Overview

General requirements for electrical work, wiring diagrams, and power supply.

Supply and Power Requirements

Procedure for providing power supply, compatibility checks, and protection devices.

Split Unit Electrical Connection

Diagram and notes for connecting mains and control wiring for the split unit.

Wiring Connections Details

Control Source Configuration

Control Source Settings (CtrS)

Configuration options for control source (3rd Party, Wall Controller, BMS, etc.) on the Outdoor Board.

Third Party Control Input

Single Speed Fan Operation Control

Wiring and configuration for third-party control of single-speed indoor fan operation.

Variable Speed Fan Operation Control

Wiring and configuration for third-party control of variable-speed indoor fan operation.

Indoor Fan Commissioning Data

Refrigerant Charging Procedures

Charging Method: Sub-cooling and Superheat

Overview of refrigerant charging methods using sub-cooling and superheat parameters.

Cooling and Heating Operation Charging

Steps to adjust refrigerant charge for optimal performance in cooling and heating modes.

Checking For Sub-cooling

Procedure to check system sub-cooling against specified ranges and adjust refrigerant charge.

Maintenance Procedures and Schedule

Maintenance Frequency Checklist

Troubleshooting Guide

Troubleshooting Common Issues

Guide to diagnose and resolve common faults like no airflow, insufficient cooling/heating, and steam emission.

Fault and Status Codes