Inspect unit, components, and accessories for damage. Check nameplate for specs.
Ensure installation complies with relevant codes, regulations, and standards.
Details on ActronAir Ducted units, energy efficiency, refrigeration circuits, evaporator, condenser, and electrical sections.
Follow instructions, use PPE, ensure proper electrical installation, and secure cables.
Disconnect power, use LOTO, beware of residual voltage, rotating fans, pinch points, and sharp edges.
Licensed technicians, recover/recycle refrigerants, follow SDS, use approved vessels.
Use reclaiming equipment, minimize emissions, achieve low vacuum (<500 microns).
Leak test all repairs, charge R-410A in liquid form, reclaim from lines.
Verify ratings, foundation, anti-vibration, clearances, wiring, and location hazards.
Download from website or access via NFC tag using a mobile device.
Diagram showing key components like fans, control panel, coil assembly, compressor, and accumulator.
Diagram and labels for single-phase control panel components (10-17kW).
Diagram and labels for three-phase control panel components (13-23 kW).
Diagram and labels for three-phase control panel with soft starter (13-23 kW).
Detailed dimensions, weight, corner weights, and minimum service/airflow clearances.
Dimensions, weight, corner weights, and clearances for CRA130S/T and CCA130S models.
Dimensions, weight, corner weights, and clearances for CRA150S/T and CCA150S models.
Dimensions, weight, corner weights, and clearances for CRA170S/T and CCA170S/T models.
Dimensions, weight, corner weights, and clearances for CRA200T/CCA200T models.
Dimensions, weight, distribution, and clearances for CRA230T/CCA230T models.
Instructions and equipment for lifting the unit using a crane safely.
Instructions and precautions for moving the unit with a forklift safely.
Steps to remove the access panel and install interconnecting field pipes.
Guidelines for R-410A refrigerant, brazing with nitrogen, and pipe length calculations.
Table showing equivalent straight pipe lengths for various elbow fittings.
Diagram and formula for calculating total equivalent field pipe length.
Tables detailing pipe sizes for single-phase and three-phase models.
Procedures for piping work to indoor and outdoor units using nitrogen bleed.
Procedures for pressure testing and triple evacuation for leak detection.
Refer to diagrams, confirm supply, protect circuits, use isolators, check voltage balance.
Table specifying circuit breaker sizes and cable requirements for different models.
Diagram showing mains wiring, control wiring, and data cable connections.
Recommended wiring diagram and table for connecting indoor/outdoor units and controllers.
Alternate wiring diagram and table for connecting indoor/outdoor units and controllers.
Diagram and table for cable lengths related to zoning configurations and options.
Wiring for LR7 Wall Control, LM-RS-2 Sensors, and AERSS Duct Sensors.
Connecting DRM input cables and defining management modes, including DRED device connection.
Setting the control source (3rd Party, Wall Controller, BMS, etc.) via the Outdoor Board menu.
Wiring and settings for third-party control of single-speed and variable-speed fan operation.
Wiring for run/fault indication and procedures for remote On/Off control.
Table and chart showing fan performance based on airflow and static pressure.
Table and chart showing fan performance based on airflow and static pressure.
Table and chart showing fan performance based on airflow and static pressure.
Table and chart showing fan performance based on airflow and static pressure.
Table and chart showing fan performance based on airflow and static pressure.
Table and chart showing fan performance based on airflow and static pressure.
Table for R-410A charge details and definitions for charging methods.
Steps to adjust refrigerant charge using service gauges for optimal performance.
Procedures to check and adjust sub-cooling and superheat for correct refrigerant charge.
Chart correlating R-410A pressure and temperature for charging calculations.
General procedures, electrical safety, fan safety, and hazardous voltage warnings.
Detailed steps for cleaning condenser coils safely and effectively.
Schedule for checking electrical and indoor unit components.
Schedule for checking outdoor unit components like casing, insulation, fan, motor, and compressor.
Troubleshooting for system not starting and no airflow from the indoor unit.
Troubleshooting for insufficient cooling/heating and steam/water emission.
Troubleshooting for temperature adjustment, noise, cooling problems, and fan operation.
Table listing fault/function codes for Outdoor CPU and LR7 Wall Controller.
List of key part numbers for various outdoor unit components across models.
Form for recording installation details, temperature settings, and fan settings.