Do you have a question about the ActronAir Classic 2 CRA100S and is the answer not in the manual?
Brand | ActronAir |
---|---|
Model | Classic 2 CRA100S |
Category | Air Conditioner |
Language | English |
Checks for damage, verifies model, serial, and electrical specs upon receiving the unit.
Installer ensures compliance with local codes, regulations, and building standards for installation and wiring.
Instructions on how to download operation manuals from the official ActronAir website.
How to access operation manuals using the NFC tag on the controller via mobile apps.
Details the components of the control panel for single-phase units, including wiring and components.
Details the components of the control panel for three-phase units, including wiring and components.
Details the control panel components for three-phase units with a soft starter option.
Provides dimensions, weight, corner weights, and minimum service/airflow clearances for the CRA100S model.
Provides dimensions, weight, corner weights, and clearances for CRA130S, CRA130T, and CCA130S models.
Provides dimensions, weight, corner weights, and clearances for CRA150S, CRA150T, and CCA150S models.
Provides dimensions, weight, corner weights, and clearances for CRA170S, CRA170T, CCA170S, and CCA170T models.
Provides dimensions, weight, corner weights, and clearances for CRA200T and CCA200T models.
Provides dimensions, weight, corner weights, and clearances for CRA230T and CCA230T models.
Details safe procedures and equipment for lifting the unit with a crane, including spreader bars.
Details safe procedures for moving the unit using a forklift, including proper tine placement.
Guidelines for piping and brazing, including R-410A precautions, nitrogen purging, and equivalent pipe length calculations.
Procedures for pressurizing the system, importance of evacuation, and diagram.
Step-by-step guide for performing a triple evacuation of the refrigeration system.
Details the wiring connections for the split unit, including mains and control wiring diagrams.
Illustrates the recommended wiring configuration for connecting indoor and outdoor units and controllers.
Illustrates an alternative wiring configuration for connecting indoor and outdoor units and controllers.
Details the wiring connections for the LR7 wall controller.
Details the wiring connections for optional LM-RS-2 remote sensors.
Details the wiring connections for optional AERSS duct sensors.
Explains how to connect and configure demand response management features.
How to control the unit using a 3rd party controller for single-speed fan operation.
How to control the unit using a 3rd party controller for variable-speed fan operation.
How to configure and use run and fault indication outputs from the outdoor board.
How to turn the system on and off remotely using a switch or relay.
Provides performance data (airflow vs. static pressure) for EVA100S/EFA100S fan commissioning.
Provides performance data (airflow vs. static pressure) for EVA130S/EFA130S fan commissioning.
Provides performance data (airflow vs. static pressure) for EVA150S/EFA150S fan commissioning.
Provides performance data (airflow vs. static pressure) for EVA170S/EFA170S fan commissioning.
Provides performance data (airflow vs. static pressure) for EVA200S/EFA200S fan commissioning.
Provides performance data (airflow vs. static pressure) for EVA230S/EFA230S fan commissioning.
Procedures for adjusting refrigerant charge for optimal cooling/heating, including gauge connection and readings.
Method for checking and adjusting sub-cooling for correct refrigerant charge.
Method for checking and adjusting superheat for optimal evaporator capacity.
Instructions for cleaning the condenser coils to maintain optimal performance.