Classic Series 2
Split Ducted Unit
Installation and Commissioning Guide - Outdoor
Model Numbers
Classic Condenser Add On Cooling Only
CRA100S
CRA130S
CRA130T
CRA150S
CRA150T
CRA170S
CRA170T
CRA200T
CRA230T
CCA130S
CCA150S
CCA170S
CCA170T
CCA200T
CCA230T
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir Classic 2 CRA100S and is the answer not in the manual?

ActronAir Classic 2 CRA100S Specifications

General IconGeneral
BrandActronAir
ModelClassic 2 CRA100S
CategoryAir Conditioner
LanguageEnglish

Summary

01. Inspection

01.01. Product Inspections

Checks for damage, verifies model, serial, and electrical specs upon receiving the unit.

01.02. Codes, Regulations and Standards

Installer ensures compliance with local codes, regulations, and building standards for installation and wiring.

02. General Information

03. Safety Instructions

04. Installation Information

INSTALLATION PREPARATION (Pre-Installation considerations)

05. Operation Manual Access

05.01. Download from website

Instructions on how to download operation manuals from the official ActronAir website.

05.02. Near Filed Communication (NFC) Tag

How to access operation manuals using the NFC tag on the controller via mobile apps.

06. Components Overview

07. Control Panel

07.01. Single Phase (10-17kW)

Details the components of the control panel for single-phase units, including wiring and components.

07.02. Three Phase (13-23 kW)

Details the components of the control panel for three-phase units, including wiring and components.

07.03. Three Phase - Soft Starter Option (13-23 kW)

Details the control panel components for three-phase units with a soft starter option.

08. Unit Dimensions and Clearances

08.01. CRA100S

Provides dimensions, weight, corner weights, and minimum service/airflow clearances for the CRA100S model.

08.02. CRA130S / CRA130T / CCA130S

Provides dimensions, weight, corner weights, and clearances for CRA130S, CRA130T, and CCA130S models.

08.03. CRA150S / CRA150T / CCA150S

Provides dimensions, weight, corner weights, and clearances for CRA150S, CRA150T, and CCA150S models.

08.04. CRA170S / CRA170T CCA170S / CCA170T

Provides dimensions, weight, corner weights, and clearances for CRA170S, CRA170T, CCA170S, and CCA170T models.

08.05. CRA200T / CCA200T

Provides dimensions, weight, corner weights, and clearances for CRA200T and CCA200T models.

08.06. CRA230T / CCA230T

Provides dimensions, weight, corner weights, and clearances for CRA230T and CCA230T models.

09. Unit Lifting Procedure

Crane Lifting Method

Details safe procedures and equipment for lifting the unit with a crane, including spreader bars.

Fork Lift Method

Details safe procedures for moving the unit using a forklift, including proper tine placement.

10. Outdoor Unit Preparation

11. Field Pipe Connection

11.01. Piping and Brazing

Guidelines for piping and brazing, including R-410A precautions, nitrogen purging, and equivalent pipe length calculations.

11.02. Pressure Testing

Procedures for pressurizing the system, importance of evacuation, and diagram.

11.03. Evacuation Procedure (Triple Evacuation)

Step-by-step guide for performing a triple evacuation of the refrigeration system.

12. Electrical Installation

12.01. Split Unit Electrical Connection

Details the wiring connections for the split unit, including mains and control wiring diagrams.

13. Maximum Cable Lengths

13.01. Wiring Configuration : Recommended

Illustrates the recommended wiring configuration for connecting indoor and outdoor units and controllers.

13.02. Wiring Configuration : Alternate

Illustrates an alternative wiring configuration for connecting indoor and outdoor units and controllers.

14. Cable Length - Zoning

15. Wiring Connections

15.01. LR7 Wall Control Wiring Connections

Details the wiring connections for the LR7 wall controller.

15.02. LM-RS-2 Optional Sensor Wiring Connections

Details the wiring connections for optional LM-RS-2 remote sensors.

15.03. AERSS Optional Duct Sensor Wiring Connections

Details the wiring connections for optional AERSS duct sensors.

15.04. Demand Response Management

Explains how to connect and configure demand response management features.

16. Control Source Configuration (CtrS)

17. Third Party Control Input (InZone Board and/or Outdoor Board)

17.01. Third Party Control Input (Single Speed Fan Operation)

How to control the unit using a 3rd party controller for single-speed fan operation.

17.02. Third Party Control Input (Variable Speed Fan Operation)

How to control the unit using a 3rd party controller for variable-speed fan operation.

17.03. Run and Fault Indication Output (Outdoor Board)

How to configure and use run and fault indication outputs from the outdoor board.

17.04. Remote On/Off

How to turn the system on and off remotely using a switch or relay.

18. Indoor Fan Commissioning via Third Party Control

18.01. EVA100S / EFA100S

Provides performance data (airflow vs. static pressure) for EVA100S/EFA100S fan commissioning.

18.02. EVA130S / EFA130S

Provides performance data (airflow vs. static pressure) for EVA130S/EFA130S fan commissioning.

18.03. EVA150S / EFA150S

Provides performance data (airflow vs. static pressure) for EVA150S/EFA150S fan commissioning.

18.04. EVA170S / EFA170S

Provides performance data (airflow vs. static pressure) for EVA170S/EFA170S fan commissioning.

18.05. EVA200S / EFA200S

Provides performance data (airflow vs. static pressure) for EVA200S/EFA200S fan commissioning.

18.06. EVA230S / EFA230S

Provides performance data (airflow vs. static pressure) for EVA230S/EFA230S fan commissioning.

19. Refrigerant Charging

19.01.02. Cooling and Heating Operation:

Procedures for adjusting refrigerant charge for optimal cooling/heating, including gauge connection and readings.

19.01.03. Checking For Sub-cooling

Method for checking and adjusting sub-cooling for correct refrigerant charge.

19.01.04. Checking for Superheat:

Method for checking and adjusting superheat for optimal evaporator capacity.

20. Maintenance

Cleaning the Condenser Coils

Instructions for cleaning the condenser coils to maintain optimal performance.

21. Maintenance Frequency Checklist

Troubleshooting Guide

22. Fault And Status Codes

23. Key Parts List

24. Start Up and Commissioning Report