MCBA PArAMeters for the sPeCiAlist
660Y1400 - A
SETTING THE PARAMETER: only accessible using the code
Factory settings Factory settings
STEP Display Parameter Description HM 25 TC HM 35 TC HM 45 TC HM 70 TC HM 85 TC HM 120 TC HM 71 HM 101 HM 201
p. 2 8
Fan speed during ignition
[rpm X 100.
Natural gas
. 36 . 36 . 36 . 39 . 39 . 44 . 35 . 42 . 37
Propane
. 36 . 36 . 36 . 39 . 39 . 44 . 32 . 38 . 32
p. 2 9
Fan speed during slow start [rpm. X 100
. 30 . 30 . 30 . 30 . 30 . 30 . 30 . 30 . 30
p. 3 0
Min. power time after start-up in CH mode [sec.
X 9,0
. 00 . 00 . 00 . 00 . 00 . 18 . 00 . 00 . 00
p. 3 2
Central heating pump over run 00 = 10 sec.
min.
. 00 . 00 . 00 . 00 . 00 . 00 . 00 . 00 . 00
p. 3 3
Domestic hot water pump over run sec. X 10,2.
. 1 1 . 1 1 . 1 1 . 1 1 . 1 1 . 1 1 . 1 1 . 1 1 . 1 1
p. 3 4
CH hysteresis on.
. 02 . 02 . 02 . 02 . 02 . 02 . 01 . 01 . 01
p. 3 5
CH hysteresis off.
. 03 . 03 . 03 . 03 . 03 . 03 . 03 . 03 . 03
p. 3 6
DHW hysteresis on.
. 00 . 00 . 00 . 00 . 00 . 00 . 0 1 . 0 1 . 0 1
p. 3 7
Burner trigger hysteresis (DHW).
. 06 . 06 . 06 . 06 . 06 . 06 . 03 . 03 . 03
p. 3 8
DHW detection hysteresis on.
. 05 . 05 . 05 . 05 . 05 . 05 . 04 . 04 . 04
p. 3 9
DHW detection hysteresis off.
. 00 . 00 . 00 . 00 . 00 . 00 . 0 1 . 0 1 . 0 1
p. 4 0
Central heating block time sec. X 10,2.
. 05 . 05 . 05 . 05 . 05 . 05 . 00 . 00 . 00