ADS-tec IRF1401 Specifications

General IconGeneral
Product TypeIndustrial Router
Cellular4G LTE
Ethernet Ports2
Input Voltage Range9-36 VDC
Protection ClassIP30
Serial Ports1 x RS232
Power Supply24 V DC

Summary

Notes

General remark

General information about the instruction manual and device usage.

Limitation of liability

Details ADS-TEC's liability limitations regarding device use and maintenance.

Manufacturer

Identifies ADS-TEC Industrial IT GmbH as the manufacturer of the product.

Relevant device documentation

Lists essential documents for device setup and operation, including manuals and data sheets.

Safety instructions

Structure of safety instructions

Explains how safety instructions are classified and presented in the manual.

Graduation of risk level

Describes how hazards are classified based on signal words and risk levels.

Explanation of used symbols

Defines warning symbols (DANGER, WARNING, CAUTION) and attention notices.

Symbols

Details symbols for battery disposal, WEEE, and protective earth connection.

Data, figures and modifications

Statement on the accuracy and subject to change nature of data, figures, and text.

Trademarks

Acknowledges software/hardware trademarks and company brand names used in the documentation.

Copyright

Outlines copyright protection and permitted usage rights for the instruction manual.

Conformity

Declares CE marking and compliance with EU directives; covers FCC Class A digital device.

Operating and safety instructions

Safety instructions

Provides safety precautions for connecting cables and performing installation work.

Operating location

Specifies requirements for the industrial operating environment and prohibits non-specified locations.

Damage due to improper use

Warns about shutting down the device if signs of damage from improper use are evident.

Warranty / repairs

States that repairs during warranty must be performed only by the manufacturer or authorized personnel.

Intended use

Defines the device's purpose for IT security, remote maintenance, and industrial applications.

Improper use

Defines improper use and states ADS-TEC is not liable for damages resulting from it.

Safety instructions

Details safety measures against electrostatic discharge and requirements for installation work.

Safety instructions on mobile radio

Covers safety warnings related to radio interference, wireless connections, and lightning strikes.

Calculation example for the transmission power (EIRP)

Provides an example calculation for Effective Isotropic Radiated Power (EIRP) and antenna gain limits.

Notes on using the device according to UL approval

Specifies UL approval requirements, including indoor use and fuse replacement by the manufacturer.

Introduction

Equipment versions

Presents a table comparing different IRF1000 series equipment versions and their interfaces.

Digital input

Explains the function of the 24V digital input for Ethernet uplink disconnection.

Eventlog

Describes the event log feature for saving and reading events locally or via a syslog server.

Mobile radio modem (optional)

Informs about the integrated LTE modem enabling mobile radio connections.

Scope of delivery

Lists the items included in the package for the industrial router and firewall.

Environmental conditions

Details the specified ambient temperature and humidity ranges for device operation and storage.

Installation

External device dimensions

Provides detailed external dimensions of the industrial router and firewall with diagrams.

Top-hat rail mounting

Explains the step-by-step procedure for mounting the device on a top-hat rail.

Optional: Attaching mobile communications antenna

Describes how to connect the mobile communications antenna to the device.

System features

General LED status displays

Provides an overview of the status of various interfaces indicated by integrated LEDs.

Operating-related LED status displays

Details LED behavior during boot-up, reset, and firmware updates.

Interface overview

Describes the interfaces of the device, including power supply and requirements.

Commissioning

Initial configuration

Outlines the initial configuration steps, requiring a PC connection via RJ45 network cable.

Manual configuration of the network adapter

Guides on configuring the network adapter's IP address and subnet mask for PC connection.

Calling up the device web interface

Explains how to access the device's web interface using its IP address and default login credentials.

Technical data

Service & support

ADS-TEC support

Provides contact information for ADS-TEC support team availability and methods.

Company address

Lists the company address, phone number, email, and website for ADS-TEC Industrial IT GmbH.

Related product manuals