EasyManuals Logo

ADT Focus 200 Plus User Manual

ADT Focus 200 Plus
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
70 –
System Operation (contd)
Sending Messages to a Pager
The FOCUS 200 PLUS system can transmit messages to up to 8 paging
services (typically one for each group). The types of messages are divided
into 4 categories: System Troubles, Point Troubles, Alarms and Open/Closes.
Additionally, the system can be programmed to attempt to dial the paging
service either once or twice (the default is twice).
The format of the pager message is as follows:
EEE GGG UUUU
EEE = Event Code
GGG = Group Number (001-008)
UUUU = User Number (for open/closes) or Point Number.
The possible event codes are:
111 = Fire Alarm
222 = Hold-up or Hostage Alarm
333 = Burglary Alarm
400 = Group failed to Turn OFF
444 = Group was Turned OFF
500 = Group Failed to Turn ON
555 = Point or System Trouble
777 = Group was Turned ON
911 = Personal Emergency (Medical
Alarm)
The following is an example of a pager message:
444 001 0025 Group 1 was turned OFF by user 25.