ADTECH9 Series CNC Maintenance Manual
- 119 -
pauses and pre-reads, please increase this value to pre-read more
instructions.
029 Inp AccSpeed Mode (1: linear acceleration/deceleration 0:S curve acceleration/deceleration)
030 'S' Speed Acceleration
Range :
Unit :
Authority : Operation admin or higher
Default :
Effective time : Instant
Note : Used to set the performance of S curve acceleration/deceleration
031 HOME check enable for alarm
032 HOME Check Enable
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 0, 1
Effective time : Instant
Note : Used to set whether prompt user to reset under certain conditions,
ensuring that the user has performed the operation;
If the value is set to 0, it won’t check, and will run directly.
033 X diameter prog enable (L series)
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 1 (L series) /0 (M series)
Effective time : Instant
Note : On lathe controller (L series), it is used to set whether the display and
programming of X axis are in radius or diameter;