TouchMix
®
XI Computer User Manual Date: 6/10/16 Doc#: 2005SA1800
Page 9
Hazardous Location - Installation Control Drawings
The following drawings provide the minimal requirements for installation of the
computer system into a hazardous environment. These drawings cover North America
(USA& Canada), ATEX (EU), and IECEx Installation sites. Additional local requirements
may apply. It is the end users responsibility to make sure the installation complies
with all applicable local, national, and international requirements.
Hazardous Location Certifications:
US: Class I, Division 2, Group C,D T4; Conforms to: ISA12.12.01
Class I, Zone 2, AEx nA [iC] IIB T4; Conforms to: UL60079-0,-11,-15
With non-incendive circuit outputs
CAN: Ex nA [iC] IIB T4; Certified to CSA60079-0,-11,-15
Class I, Division 2, Group C,D T4; Certified to: CSA213
With non-incendive circuit outputs
ATEX: II 3G Ex nA [iC] IIB T4 Gc; 0°C ≤ Ta ≤ 45°C – ITS16ATEX28440
IECEx: Ex nA [iC] T4 Gc; IP54; 0°C ≤ Ta ≤ 45°C - IECEx ETL15.0060