6.1.10. The normal operating temperature is 0-40 ℃.
6.2 Storage conditions: Store the UPS covered and upright in a cool and dry location,
with its battery fully charged. Before storing, charger the UPS for at least 4 hours. Remove
any accessories in the accessory slot and disconnect any cables connected to the computer
interface port to avoid unnecessary draining the battery.
6.3 To extend the storage:
6.3.1. During the environment where the ambient temperature is -15 to +30 ℃ (+5 to
+86 ℉), charge the UPS‘s battery every 6 months.
6.3.2. During the environment where the ambient temperature is +30 to +45 ℃ (+86 to
+113 ℉), charge the UPS‘s battery every 3 months.
7. BATTERY AND BATTERY CABINET
7.1 Battery’s life of UPS
The battery’s life of UPS is about 3-6 years under normal usage.
7.2 Installation of battery cabinet and UPS (For AL and AXL models only):
Please follow the listed steps to complete the installation.
7.2.1 Turn off the UPS and remove the connector metal cover from the back panel of
UPS.
7.2.2 Connect the battery cabinet’s DC wire to the UPS and fix the motel cover via a
screwdriver. Beside this, make sure the connection is reliable.
7.2.3 Turn on the UPS and plug the loads behind the UPS.
CAUTION: Do not dispose of battery in fire.
CAUTION: Do not attempt to open the battery.
CAUTION: The following precautions should be taken when replacing the battery
a. Remove watches, rings, etc…
b. Use tools with insulated handles
APPENDIX A TROUBLESHOOTING
Problems Possible Reasons Solutions
Input power source
mistake
Check out the power source
Non-fuse switch on the
rear panel hasn't
been opened
Press the non-fuse switch to its "on"
position
UPS can't operate
after
pressing
On/Off
switches
No lights on, no
warning
sounds
Time of pressing the ON
button is too
short
Keep pressing the ON button over 1
second