Cleaning the filter housing
Wash the filter housing manually using a
mild detergent and a soft cloth. You can
also wash it in the dishwasher.
Cleaning the filter
1. Wash the filter in warm water without
any cleaning agents. Detergents can
damage the odour filtration. You can
use a soft sponge, a soft cloth, or a
non-abrasive cleaning brush to
remove food remains, if necessary.
You can also wash the filter in a
dishwasher at 65-70 °C (using a
program longer than 90 min), without
detergents and without dishes in the
same load.
2. Dry the filter in the oven for 20-30
min at 70 °C. Place the filter on the
middle wire shelf. Make sure to use a
non-fan oven function. Alternatively,
you can leave the filter to dry
overnight at room temperature. The
filter needs to be fully dried before
reassembly.
3. Reassemble the filtering unit and put
it back inside the hood cavity.
Regenerating the filter
1. Clean the filter first, as described
above in step 1.
2. Put the filter in the oven set to 80-110
°C for 60 min. Place the filter on the
middle wire shelf. Use a non-fan
oven function.
3. Reassemble the filtering unit and put
it back inside the hood cavity.
4. Press briefly to reset the counter.
The counter restarts.
10. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
10.1 What to do if...
Problem Possible cause Remedy
You cannot activate or op‐
erate the hob.
The hob is not connected to
an electrical supply or it is
connected incorrectly.
Check if the hob is correctly
connected to the electrical
supply.
The fuse is blown. Make sure that the fuse is the
cause of the malfunction. If the
fuse is blown again and again,
contact a qualified electrician.
You did not set the heat set‐
ting for 60 seconds.
Activate the hob again and set
the heat setting in less than 60
seconds.
You touched 2 or more sen‐
sor fields at the same time.
Touch only one sensor field.
Pause operates. Refer to "Pause".
There is water or fat stains
on the control panel.
Clean the control panel.
www.aeg.com26