Setting Description
0 - 100 Valid value
Parameter 8: Percentage change in wattage (Whole HEM)
Percentage change in wattage to induce a automatic report
Size: 1 Byte, Default Value: 10
Setting Description
Parameter 9: Percentage change in wattage (Clamp 1)
Percentage change in wattage to induce a automatic report
Size: 1 Byte, Default Value: 10
Setting Description
0 - 100 Valid value
Parameter 10: Percentage change in wattage (Clamp 2)
Percentage change in wattage to induce a automatic report
Size: 1 Byte, Default Value: 10
Setting Description
0 - 100 Valid value
Parameter 11: Percentage change in wattage (Clamp 3)
Percentage change in wattage to induce a automatic report
Size: 1 Byte, Default Value: 10
Setting Description
0 - 100 Valid value
Parameter 13: Enable /disable reporting
Enable /disable reporting CRC-16 Encapsulation Command
Size: 1 Byte, Default Value: 0
Setting Description
0 disable
1 enable
Parameter 100: Reset parameter 101-103
Size: 1 Byte, Default Value: 0
Setting Description
1 reset parameter 101-103
Parameter 101: Setting automatic report flags Group 1
Example: 1 + 1024 = Value 1025 If you want to report everthing, you would add the whole table together and set in to 101.
Please, see table in usage.
Size: 4 Byte, Default Value: 0
Setting Description
1 Report Total HEM - KWH
2 Report Total HEM - Watt
4 Report Total HEM - Voltage
8 Report Total HEM - Current
Parameter 102: Setting automatic report flags Group 2
Example: 1 + 1024 Value 1025 If you want to report everthing you would add the whole table together and set in to 102