CHAPTER 4: Troubleshooting
22
4.5 No resistance or Incorrect resistance (continued)
B) If the ECB motor can move, the resistance can be adjusted. If the resistance is too
strong, check the flywheel to make sure that the gap between the orange block and the
bottom is within 1-2 mm.
If the gap is bigger than 1-2 mm, the resistance will be stronger than normal. Adjust the cable to
the correct gap range.
3. If steps 1 & 2 do not fix the issue, the inside magnet is defective. Replace the inside
magnet.