4.5
No resistance or Incorrect resistance
Symptom:1. The resistance cannot be adjusted during exercise.
2. The resistance is reversed or too strong.
Reason:
1. Speed sensor wire is defective.
2. Console cable or ECB motor is defective.
3. ECB motor’s steel rope is positioned incorrectly.
4. Inside magnet is defective.
Solution:
1. Turn on the console and check the ECB motor.
In resistance level 1, the head of the steel rope should point to the top right side (around 45
degree). If the head of the steel rope points to bottom left side, the resistance will be
reversed. Adjust the head of the steel rope to the correct position.
2. Press key “+” to adjust the resistance.
A) If ECB motor cannot move, the resistance will not be changed. The ECB motor or
console cable is defective. Make sure the console cable inserted in the ECB motor.
Next, try to reconnect the console cable. If the issue remains, replace the console
cable. If the issue remains after replacing the console cable, replace the ECB motor.