EasyManua.ls Logo

AGCO Gleaner S97 - Page 28

AGCO Gleaner S97
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Grain loss
Grain loss over cleaning shoe (cont.)
Possible Cause Correction
Incorrect chaffer for cropbeing
harvested.
Round end, shallow tooth 1.125” (28.6
mm) shoe spacing - used in all crops
except corn.
Round end, deep tooth 1.625” (41.3
mm) spacing - generally used in corn
but has also been found to provide
desired cleaning in some crops such
as soybeans and high moisturecereal
grains where more air volume is
desired.
Square end, deep tooth 1.625” (41.3
mm) spacing - generally used in high
moisture corn to remove pieces ofcob
from the grain tanksample.
Incorrect air pattern.
Inspect fan, fan choke, shoe airduct
and splitterlocation.
Grain loss present when enteringand/
or leaving the crop.
This situation is usually normal because
the cleaning system should be adjusted
to provide min. grain loss when in a
fully loadedcondition.
25