Specific Command Summary Specific Commands
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition 47
:SENSe[n][:CHANnel[m]]:CORRection
[:LOSS][:INPut][:MAGNitude]/? Sets or returns the value of correction data for a sensor. page 92
:COLLECT:ZERO Executes a zero calibration of a sensor module. page 92
:COLLECT:ZERO? Returns the current zero state of a sensor module. page 93
:COLLECT:ZERO:ALL Executes a zero calibration of all sensor modules. page 93
:SENSe[n][:CHANnel[m]]:FUNCtion
:PARameter:LOGGing/? Sets or returns the number of samples and the averaging time,
t
avg
, for logging.
page 94
:PARameter:MINMax/? Sets or returns the minmax mode and the window size. page 95
:PARameter:STABility/? Sets or returns the total time, delay time and the averaging time,
t
avg
, for stability.
page 96
:RESult? Returns the data array of the last function. page 97
:RESult:BLOCk? Returns a specified binary block from the data array for the last
power meter data acquisition function.
page 98
:RESult:MAXBlocksize? Returns the maximum block size for power meter data acquisition
functions.
page 98
:RESult:MONitor? For return loss module, returns monitor diode data array of last
function.
page 99
:STATe/? Enables/disables the function mode or returns whether the func-
tion mode is enabled.
page 100
:THReshold/? Sets or returns the threshold value and the start mode. page 101
:SENSe[n][:CHANnel[m]]:POWer
:ATIMe/? Sets or returns the average time of a sensor. page 101
:RANGe[:UPPer]/? Sets or returns the most positive signal entry expected for a sen-
sor.
page 102
:RANGe:MONitor[:UPPer]/? Sets or returns the range of the monitor diode within a return loss
module.
page 103
:RANGe:AUTO/? Sets or returns the range of a sensor to produce the most dynam-
ic range without overloading.
page 104
:REFerence/? Sets or returns the reference level of a sensor. page 105
:UNIT/? Sets or returns the units used for absolute readings on a sensor. page 108
:WAVelength/? Sets or returns the wavelength for a sensor. page 108
Table 4 Specific Command Summary (continued)
Command Description Page

Table of Contents

Other manuals for Agilent Technologies 8166B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8166B and is the answer not in the manual?

Agilent Technologies 8166B Specifications

General IconGeneral
BrandAgilent Technologies
Model8166B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals