EasyManuals Logo

Agilent Technologies 8166B Programming Guide

Agilent Technologies 8166B
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Specific Commands Specific Command Summary
50 Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition
[:SOURce[n]][:CHANnel[m]:]READout
:DATA? Returns number of datapoints returned by the
[:SOURce[n]][:CHANnel[m]]:READout:POINts? command.
page 129
:DATA:BLOCk? Returns a specified binary block from either a lambda logging op-
eration, or maximum power at wavelength characteristic.
page 129
:DATA:MAXBlocksize? Returns the maximum blocksize that a lambda logging, or maxi-
mum power at wavelength characteristic will return.
page 129
:POINts? Returns the data as a binary stream from either a lambda logging
operation or the maximum power the laser can produce at each
wavelength.
page 130
[:SOURce[n]][:CHANnel[m]:]WAVelength
[:CW[l]:FIXED] Sets the absolute wavelength of a source. page 130
[:CW[l]:FIXED[l]]? Returns the absolute wavelength of a source. page 131
:FREQuency[l]/? Sets the frequency difference used to calculate a relative wave-
length for a source.
page 134
:REFerence[l]? Returns the reference wavelength of a source. page 135
[:SOURce[n]][:CHANnel[m]:]WAVelength:CORRection
:ARA Realigns the laser cavity. page 131
:ARA:ALL Realigns the laser cavity of every tunable laser source in the
mainframe.
page 132
:AUTocalib Sets or returns tunable laser source Auto Calibration state. page 132
:ZERO Executes a wavelength zero. page 132
:ZERO:ALL Executes a wavelength zero on every tunable laser source in the
mainframe.
page 133
:ZERO:TEMPerature:ACTual? Reports the current lambda zero temperature page 133
:ZERO:TEMPerature:DIFFerence? Reports the temperature difference required to trigger an auto
lamda zero.
page 134
:ZERO:TEMPerature:LASTzero? Reports the temperature at which the last auto lamda zero took
place.
page 134
:ZERO:AUTO Forces an auto lamda zero. This is quicker than the equilavent
manual process.
page 134
[:SOURce[n]][:CHANnel[m]:]WAVelength:REFerence
:DISPlay Sets the reference wavelength of a source to the value of the out-
put wavelength.
page 135
Table 4 Specific Command Summary (continued)
Command Description Page

Table of Contents

Other manuals for Agilent Technologies 8166B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8166B and is the answer not in the manual?

Agilent Technologies 8166B Specifications

General IconGeneral
BrandAgilent Technologies
Model8166B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals