4.
Po
wer
Sensor
Configuration
and
Calibration
F
actor
File
Description
This utilit
yis
used for
creating and
editing the
les
that
store
p
o
w
er
sensor
calibration
factors.
The
p
o
w
er
sensor
calibration
factors
are
used
in
the
\P
o
w
er Flatness"
and \Step
A
tten
uator"
performance
tests and
adjustment
pro cedures.
This
data
can
b
e
stored
to
the
directory or
disk
for
future
use.
The
p
o
w
er
meter/p
o
w
er
sensor
conguration
utilit
y
is used
to
dene
whic
h
p
o
w
er
sensors,
b
y serial
num
ber,
are actually
used
when
the
automated
test
is
run. Although
you
may
enter
and
store
calibration
factors
for
sev
eral
p
o
w
er
sensors,
the
program
will
use
only
the
p
o
w
er
sensors
that
y
ou
ha
v
e
iden
tied b
y serial
num
ber
in
the
conguration
utilit
y
.
Loading
Sensor
Calibration
F
actors
The
service
softw
are program
for
loading
sensor
calibration
factors
is
unfriendly
.
F
ollo
wing
the
steps
outlined
should
result
in
a
successful
en
try
.
Do
not
h
urry
or
skip
steps.
To
Load Sensor
Cal
F
actors:
1.
Load
the
8360
Service
Softw
are and
run.
2.
A
t
the
\T
est
Men
u"
selected
one
of
the
follo
wing:
\Po
w
er
Flatness
and
Accuracy
T
est",
\Step
A
tten
uator
Flatness
T
est",
\P
o
w
er
Flatness
Adjust",
or
\Step
A
tten
uator
Flatness
Adjust".
3.
Press
the
\Help"
k
ey
(F2)
when
it
app
ears
on
the function
k
eys
to
get
to
the
\Help
Men
u"
where
the
\Pm
tr
Cong"
(P
o
w
er
Meter
Conguration)
and
\Pm
tr
Cal
F
actors"
selections
are lo
cated.
4.
Scroll
do
wn
to
and
select
[2]
\Pmtr
Cong". The
p
o
w
er
meter
conguration
routine
is
only
used
to
select
sensor
serial
n
um
b
ers
(mo
del
n
umb
ers are
xed). After
selecting \Pm
tr
Cong"
the screen
will
displa
y
a
list
of
mo
del
and
serial
n
um
b
ers
the
program
will
use
during
the
test.
Imp
ortan
t Notes
for Editing
the Selections:
No
new mo
del n
umb
ers can
be
added. The
program
only
recognizes
the
mo
del
n
um
b
ers
listed
and
will
stop
if
other
mo del
n
um
b
ers
are
en
tered.
Mo del n
umbers can not b e c
hanged. Only the serial n
umbers can be c
hanged in
this
menu. Use serial n
umbers to trac
k dieren
t sensor mo
del n
umbers.
Only edit sensor serial n
umbers in this men
u.
Always exit the program b
y selecting [17] \Sa
ve Conguration" and, then, pressing
\Done". A bug in the program ma
yerase mo
del n
umbers if this is not done. If a mo del
number is missing create a new w
orking disk n
umber 2 using the master disk or purge
\PMTRCONF" le from the working disk and copy the \PMTRCONF" le backtothe
working disk from the master disk.
The frequency range of the instrument determined which sensor mo del numb ers listed
will b e used during the test. The serial numb er determines which cal factors will be
used. The follo wing list explains whichmodelnumbers are used when.
Agilent 8360 Automated Tests 5-21

Table of Contents

Other manuals for Agilent Technologies 8360 B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8360 B Series and is the answer not in the manual?

Agilent Technologies 8360 B Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8360 B Series
CategoryPortable Generator
LanguageEnglish

Related product manuals