138 Software Library Reference Manual for VME 429
Section 6 - Receiver Functions
6.11 Api429CmdRxStart
P
P
r
r
o
o
t
t
o
o
t
t
y
y
p
p
e
e
:
:
AiUInt8 Api429CmdRxStart( AiUInt8 b_Module, AiUInt8 b_Chn );
D
D
r
r
i
i
v
v
e
e
r
r
C
C
o
o
m
m
m
m
a
a
n
n
d
d
:
:
API429_RX_START (0x93)
P
P
u
u
r
r
p
p
o
o
s
s
e
e
:
:
This function starts the receiver and monitor operation on the selected API429
receiver and monitor channel. The receiver and monitor will be started in
corresponding mode of the "Api429CmdRxIni command" and "Api429CmdRmIni
command".
I
I
n
n
p
p
u
u
t
t
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
C
C
h
h
n
n
Channel Number
Value Description
1..32
API429 receiver channel number
O
O
u
u
t
t
p
p
u
u
t
t
none
R
R
e
e
t
t
u
u
r
r
n
n
V
V
a
a
l
l
u
u
e
e
Value Constant Description
0 API429_CMD_OK
Execution success
1 API429_CMD_ERR
Execution error