Software Library Reference Manual for VME 429 79
Section 5 – Transmitter Functions
5.2 Api429CmdTxFrmTimeIni
P
P
r
r
o
o
t
t
o
o
t
t
y
y
p
p
e
e
:
:
AiUInt8 Api429CmdTxFrmTimeIni( AiUInt8 b_Module, AiUInt8 b_Chn, AiUInt16 w_Ftm );
D
D
r
r
i
i
v
v
e
e
r
r
C
C
o
o
m
m
m
m
a
a
n
n
d
d
:
:
API429_TX_FTIME_INI (0x72)
P
P
u
u
r
r
p
p
o
o
s
s
e
e
:
:
This command defines the minor frame time of the selected API429 transmitter
channel in 5ms steps.
Note: After a Api429CmdReset command or the Api429CmdTxIni command the
minor frame time is set to 100ms.
Note: This command is obsolete. Please use Api429CmdTxFrmTimeIniEx instead.
I
I
n
n
p
p
u
u
t
t
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
C
C
h
h
n
n
Channel Number
Value Description
1..32
API429 transmitter channel number
A
A
i
i
U
U
I
I
n
n
t
t
1
1
6
6
w
w
_
_
F
F
t
t
m
m
Minor Frame Time
Value Description
1..13107
Minor Frame Time in 5ms steps
Range: 5ms..65.535s
O
O
u
u
t
t
p
p
u
u
t
t
none
R
R
e
e
t
t
u
u
r
r
n
n
V
V
a
a
l
l
u
u
e
e
Value Constant Description
0 API429_CMD_OK
Execution success
1 API429_CMD_ERR
Execution error

Table of Contents

Related product manuals