78 Software Library Reference Manual for VME 429
Section 5 – Transmitter Functions
5.1 Api429CmdTxAmpIni
P
P
r
r
o
o
t
t
o
o
t
t
y
y
p
p
e
e
:
:
AiUInt8 Api429CmdTxAmpIni( AiUInt8 b_Module, AiUInt8 b_Chn, AiUInt8 b_Ampl );
D
D
r
r
i
i
v
v
e
e
r
r
C
C
o
o
m
m
m
m
a
a
n
n
d
d
:
:
API429_TX_AMP_INI (0x71)
P
P
u
u
r
r
p
p
o
o
s
s
e
e
:
:
This command defines the output amplitude of the selected API429 transmitter
channel via a D/A converter.
Note: The transmitter output amplitude cannot be changed for APM429 and
AMC429 boards!
In this case a call to this function has no effect!
Note: After a Api429CmdReset command or the Api429CmdTxIni command the
related D/A converter is loaded with 0x7A which corresponds to an output
voltage of 9.0 Volt (line to line).
I
I
n
n
p
p
u
u
t
t
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
C
C
h
h
n
n
Channel Number
Value Description
1..32
API429 transmitter channel number
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
A
A
m
m
p
p
l
l
Amplitude Control
Value Description
0..149
Corresponds to an amplitude in the range of 0 to appr. 11
Volts (peak to peak) line to line.
Note: The output Voltage can be estimated from the amplitude setting using the
following formula:
U
out
= (0..149) * 0.074 Volt
O
O
u
u
t
t
p
p
u
u
t
t
none
R
R
e
e
t
t
u
u
r
r
n
n
V
V
a
a
l
l
u
u
e
e
Value Constant Description
0 API429_CMD_OK
Execution success
1 API429_CMD_ERR
Execution error

Table of Contents