AIMS Power www.aimscorp.net
The Global LF Series is designed with extraordinarily low idle power consumption which is only a mere
0.8-1.8% of its rated power.
Global LF Series Idle Power Consumption (in Watts)
Model NO Power Saver Off Power Saver On (3Secs) Power Saver On (30Secs)
PICOGLF10W12V230V 12.5 7.5 5.3
PICOGLF10W12V120V 12.5 7.5 5.3
PICOGLF10W24V230V 15 8.4 5.4
PICOGLF10W24V120V 16.5 9 6
PICOGLF15W12V230V 12.5 7.5 5.3
PICOGLF15W12V120V 13.5 8 5.8
PICOGLF15W24V230V 15 8.4 5.4
PICOGLF15W24V120V 16.5 9 6
PICOGLF20W12V230V 25 11.7 5.7
PICOGLF20W12V120V 28 12.7 5.8
PICOGLF20W24V230V 24.5 11.5 5.7
PICOGLF20W24V120V 26.5 12.2 5.8
PICOGLF20W48V230V 25 11.7 5.7
PICOGLF20W48V120V 28 12.7 5.8
PICOGLF30W12V230V 50 20 6.5
PICOGLF30W12V120V 55 21.7 6.7
PICOGLF30W24V230V 38.5 16.2 6.2
PICOGLF30W24V120V 46.5 18.9 6.4
PICOGLF30W48V230V 45 18.4 6.4
PICOGLF30W48V120V 50 20 6.5
PICOGLF40W12V120V 44.5 18.2 6.4
PICOGLF40W24V230V 48 19.4 6.5
PICOGLF40W24V120V 52.5 20.9 6.6
PICOGLF40W48V230V 48 19.4 6.5
PICOGLF40W48V120V 55.5 21.9 6.7
PICOGLF50W24V230V 62.5 24.2 7
PICOGLF50W48V230V 68.5 26.2 7.2
PICOGLF60W24V230V 76.8 29 7.4
PICOGLF60W48V230V 80.7 30.3 7.6
When in the search sense mode, the green power LED will blink and the inverter will make a ticking sound.
At full output voltage, the green power LED will light steadily and the inverter will make a steady humming
sound. When the inverter is used as an “uninterruptible” power supply the search sense mode or Power
Saver On” function should be defeated.
Exceptions
Some devices when scanned by the load sensor cannot be detected. Small fluorescent lights are the most
common example. (Try altering the plug polarity by turning the plug over.) Some computers and
sophisticated electronics have power supplies that do not present a load until line voltage is available. When
this occurs, each unit waits for the other to begin. To drive these loads either a small companion load must